Impecca ISFC421524 Manuál

Procházejte online nebo si stáhněte Manuál pro ne Impecca ISFC421524. Impecca ISFC421524 Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 80
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Flex Series R410A GMV Multi
VFR System-Indoor Unit (For
North America) Compact Panel
Cassette Type Indoor Unit
Thank you for choosing Air Conditioners, please read this owner’s manual carefully before operation
and retain it for future reference. If you have lost the Owner’s Manual, please contact the local agent or
visit www.Impecca.com for an electronic version.
Impecca reserves the right to interpret this manual which will be subject to any change due to
product
improvement without further notice.
Impecca reserves the final right to interpret this manual.
Owner's Manual
Air Conditioners
Model:
ISMI-C15
v. 1.1
Zobrazit stránku 0
1 2 3 4 5 6 ... 79 80

Shrnutí obsahu

Strany 1 - Cassette Type Indoor Unit

Flex Series R410A GMV Multi VFR System-Indoor Unit (For North America) Compact Panel Cassette Type Indoor UnitThank you for choosing Air Conditione

Strany 2 - User Notice

Install of The Compact Panel Cassette Type Indoor Unit7Fig.112.8 Electrical wiringNote:The power of the entire indoor unit must be connected in outdoo

Strany 3

Install of The Compact Panel Cassette Type Indoor Unit82.9 Install the panel(1). Set the panel to the indoor unit body by matching the position of the

Strany 4 - 1 Safety Information

Install of The Compact Panel Cassette Type Indoor Unit9Air leakAir leak from ceilingWater condensatation, water dropFig.14② .If gap still exist betwe

Strany 5 - ISMI-C15

Constitutes and Names of Parts of Compact Panel Cassette Type Indoor Unit 103 Constitutes and Names of Parts of Compact Panel Cassette Type Indoor Uni

Strany 6 - 2.3 Important notice

Working Temperature Range114 Working Temperature RangeWorking Temperature RangeIndoor side state Outdoor side staeDry bulb temp. ℃Wet bulb temp. ℃Dry

Strany 7

Malfunction Debarring 125 Malfunction DebarringWarning!◆Cut down the main power switch immediately if malfunction (such as smell the burning odoretc.)

Strany 8 - 2.7 Drainage hose

Malfunction Debarring135.2 InstructionIf problem still cannot found out after above checking, please contact service center and instruct phenomena and

Strany 9

Maintenance Method 146 Maintenance MethodWhen air conditioner won’t be used for a long time, please cut off the main power supply of air conditioner.W

Strany 10 - 2.8 Electrical wiring

Maintenance Method15(5). Close air inlet grille (Refer to the 1st step)Maintenance Method Fig.19 Fig.206.2 Clean air inlet grille(1). Open air inlet

Strany 11 - 2.9 Install the panel

Maintenance Method 16Function and usage period for air purifying◆Could adsorb CO, CO2, benzene, aldehydes and odor of gasoline etc..◆Could adsorb dele

Strany 12 - Air leak from ceiling

User Notice◆When operating, the entire capacity of the cooperating indoor unit should be not largerthan 150% of outdoor unit. Otherwise, it will cause

Strany 13 - Indoor Unit

© 2016 Impecca, a division of LT Inc., Wilkes Barre, PA.

Strany 14 - 4 Working Temperature Range

Thank you for choosing Commercial Air Conditioners, please read thisowner’s manual carefully before operation and retain it for future reference.Comme

Strany 15 - 5 Malfunction Debarring

User Notice◆The total capacity of the indoor units which runs at the same time can not exceed 150% ofthat of outdoor units; otherwise, the cooling (he

Strany 16 - 5.4 After-sales Service

Contents1 Safety Precautions ... 12 Installation of the Cassett

Strany 17 - 6 Maintenance Method

Flex Series for North America11 Safety PrecautionsPlease read this manual carefully before using this unit, and operate it correctly according to t

Strany 18 - 6.2 Clean air inlet grille

Flex Series for North America22 Installation of the Cassette Type Indoor Unit2.1 Schematic Diagram of Installation SpacesISMI-C24ModelH260unit:mm>20Wa

Strany 19 -  WWW.IMPECCA.COM

Flex Series for North America3 2). Keep the air conditioner far from the kitchen so that the lampblack would not be indraft by the air conditioner.2.3

Strany 20

Flex Series for North America42.5 Main Body of Hoisting Air Conditioner(1). The primary step for installing the indoor unit.◆When attach the hoisting

Strany 21 - (For North America)

Flex Series for North America5and torque wrench. as shown in Fig.5.◆When connect, smear both inside and outside of the are nut with freeze motor oil,

Strany 22

Flex Series for North America6formation of air bubble.◆If drain hose cannot has enough drooping gradient, drain raising pipe should be added.◆To preve

Strany 23 - Contents

Contents1 Safety Information ...12 Install of The Compact Panel Cass

Strany 24 - 1 Safety Precautions

Flex Series for North America7Drain hose(attachment)Below 500mmBelow 75mm Fig.9◆Please install the drain hose according to the following process if se

Strany 25 - Flex Series for North America

Flex Series for North America8◆Connection wiring (communication):①Open electric box cover(1), drag the wiring (communication)from the rubber plug A, a

Strany 26

Flex Series for North America9GWHD(42)ND3AOPOWERINDOOR UNIT AINDOOR UNIT BINDOOR UNIT CINDOOR UNIT DOUTDOOR UNITINDOOR UNIT EXT2XT1XT3XT4XT5XT6NLGGGGG

Strany 27

Flex Series for North America10(3). Screw the 4 hexagon head screws under the latches in about 15mm. (The panel would rise)(4). Adjust the panel

Strany 28 - 2.7 Drain Hose

Flex Series for North America11Air leakAir leak from ceilingWater condensatation, water dropFig.14②.If gap still exist between ceiling and decoration

Strany 29

Flex Series for North America123 Parts and Components of Cassette Type Indoor Unit Air outlet ventAir filter, purifire(in air inlet grille)Air inlet

Strany 30

Flex Series for North America134 Working Temperature RangeWorking Temperature RangeIndoor side state ℉(℃)Outdoor side state℉(℃)Dry bulb temp. ℉(℃)Wet

Strany 31

Flex Series for North America145 Trouble Shooting Warning!◆Cut down the main power switch immediately if malfunction (such as smell the burning odoret

Strany 32

Flex Series for North America15★The following circumstance doesn't belong to malfunction“Malfunction” ReasonAir conditioner doesn’t run Start up

Strany 33

Flex Series for North America166 Maintenance MethodWhen the unit won’t be used for a long time, please cut off the main power supply of air conditione

Strany 34

Safety Information11 Safety InformationPlease read this manual carefully before use this unit, and operate it correctly according to the guide in this

Strany 35

Flex Series for North America17Fig. 20 Fig. 216.2 Clean Air Inlet Grille(1). Open air inlet grille (the same with the 1st step of Clean Air Filter)(2)

Strany 36

Flex Series for North America18Function and usage period for air purifying◆Adsorb CO, CO2, benzene, aldehydes and odor of gasoline etc..◆Adsorb poison

Strany 37 - 5 Trouble Shooting

Flex Series Outdoor UnitOwner's ManualCommercialAirConditionersModel: ISMO-4221Thank you for choosing our air conditioner, please read this O

Strany 38

Preface Impecca Flex System adopts the cutting-edge manufacturing technology and takes globalacknowledged, environmental-friendly R410A as

Strany 39

Contents 1 Safety Precautions... 1 2 Product Introduc

Strany 40 - 6.2 Clean Air Inlet Grille

Flex series1 1 Safety PrecautionsThis is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messag

Strany 41 - Technical Support

Flex Series2 Impecca is not responsible of personal injury or equipment damage caused by improper insta llation and commission, unnecessa

Strany 42 - Outdoor Unit

Flex Series3 2.2 Combinations for outdoor and indoor units Wall MountedIndoor UnitWall MountedIndoor UnitCassettle TypeIndoor UnitFloor/ Ceiling Indoo

Strany 43 - Preface

Flex Series 2.4 The range of production working temperature Table 3 Cooling Working range Outdoor temperature 0~118℉ Heating Working range Outdoor t

Strany 44

Flex Series5 3.3 Piping Connection The maximum pipe length is shown in the following table. When the distance between units (piping length)

Strany 45 - Flex series

Install of The Compact Panel Cassette Type Indoor Unit22 Install of The Compact Panel Cassette Type Indoor Unit2.1 Schematic diagram of installation s

Strany 46 - 2 Product Introduction

Flex Series6 4.2 Installation of the Connection Pipe Connecting piping for indoor unit and outdoor unit are in manifold mode. (As shown below).

Strany 47

Flex Series7 Allowable Length and Height Fall of the Refrigerant Pipe Table 7 Allowable Value Fitting Pipe Total length (actual length) of fitting pip

Strany 48

Flex Series 8 After the pipe is protected well enough, never bend it to form a small angle; otherwise it would crack or break. (3)Wrap the Pipe with T

Strany 49 - 4 Installation Instruction

Flex Series9 (2) Calculation of the Additional Refrigerant ChargeAdditional Refrigerant Charge=(ΣLength of Liquid Pipeφ0.375×54+ΣLength of Liquid Pipe

Strany 50

Flex Series 10 1) The mistake connecting line will result in malfunction. After the electrical wiring working, ensure the wirebetween t

Strany 51

Flex Series11 5 Troubleshooting 1) In the event of abnormal conditions (like, stinky smell), please shut off the main power supply immediately

Strany 52

Flex Series12 6 The conditions listed below are not classified into errors. Table 10 Conditions Causes The unit does not run When restart the unit soo

Strany 53

Flex Series13 running next operation Mode conflict COOL or HEAT mode can not be operated When the indoor operating mode conflicts with that of outdoor

Strany 54

Flex Series147 Troubleshooting The error code will be displayed on the wired controller and the main board of the outdoor unit The meaning of each err

Strany 55 - 5 Troubleshooting

Flex Series15 8 Maintenance 8.2 Drain Pipe Regularly check if the drain pipe is clogged in order to drain condensate smoothly. 8.3 Notice before Seaso

Strany 56

Install of The Compact Panel Cassette Type Indoor Unit32.3 Important notice ◆To guarantee the good performance, the unit must be installed by professi

Strany 57

Before contacting customer support, please see the troubleshooting guide above. Visit our website to contact us, find answers to Frequently Asked Ques

Strany 59 - 8.1 Outdoor heat exchanger

Thank you for choosing Impecca Air Conditioners. Please read this owner’s manual carefully before operation and retain it for future reference.Wired C

Strany 60

User NoticeƹƹƹƹƹƹPlease carefully read this manual before installation and use of this product (QVXUHthere is separate SRZHUVXSSO\IRUHDFKLQGRRUX

Strany 61

Contents1 Display Section... 11.1 Controller's LCD

Strany 62 - User's Manual

11 Display SectionFig1.1.1 Diagram of wired controller1.1 LCD Display of Wired ControllerFig.1.1.2 LCD displayWired Controller IS-TT850

Strany 63

21.2 Instruction to LCD DisplayTable 1.1No. Symbols Description1Swing function2Air exchange function (this function is yet unavailable for this unit).

Strany 64

32 Buttons2.1 Layout of Buttons2.2 Functions of ButtonsTable 2.1No. Name Function1 Enter/Cancel Function selection and cancellation.2 ŸķRunning tempe

Strany 65 - 1 Display Section

43 Operation Instructions3.1 On/OffPress On/Off button to toggle your A/C's power.Note: The state shown in Fig.3.1.1 indicates the “Off” state of

Strany 66 - Wired Controller IS-TT850

53.4 Fan SettingWhile the unit is powered on, press Fan and then fan speed of the indoor unit will change circularly as shown in Fig.3.4.1.Low MiddleH

Strany 67 - 2 Buttons

Install of The Compact Panel Cassette Type Indoor Unit4 ◆Install the install cardboard on the unit by bolt (3 piece), and x the angle of the drainage

Strany 68 - 3 Operation Instructions

6Timer on setting under the “Off” state of the unit is shown as Fig.3.5.2.Fig.3.5.2 Timer on Setting under the “Off” State of the Unit7LPHUUDQJH

Strany 69 - 3.5 Timer Settings

73.6 Swing SettingSwing On: Press Function under on state of the unit to activate the swing function. In this case, ZLOOEOLQN$IWHUWKDWSUHVV(Q

Strany 70

83.7 Sleep SettingSleep on: Press Function under the On state of the unit till the unit enters the Sleep setting VWDWH$IWHUWKDWSUHVV(QWHU&D

Strany 71 - 3.6 Swing Setting

93.8 Turbo SettingTurbo function: The unit at the high fan speed can realize quick cooling or heating so that the room temperature can quickly approac

Strany 72 - 3.7 Sleep Setting

103.9 E-heater SettingE-heater (auxiliary electric heating function): In the Heating mode, E-heater is allowed to beWXUQHGRQIRULPSURYHPHQWRIHI¿FL

Strany 73 - 3.8 Turbo Setting

113.10 Blow SettingBlow function: After the unit is turned off, the water in evaporator of indoor unit will be automatically evaporated to avoid milde

Strany 74 - 3.9 E-heater Setting

123.11 Other Functionsa. Lock8SRQVWDUWXSRIWKHXQLWZLWKRXWPDOIXQFWLRQRUXQGHUWKH³2II´VWDWHRIWKHXQLWSUHVVŸDQGźatthe same time for 5s t

Strany 75 - 3.10 Blow Setting

13168 91073 452Fig.4.2Fig.4.2 shows the installation steps of the wired controller, but there are some issues that need your attention.1) Prior to the

Strany 76 - 3.11 Other Functions

14and connection lines between the indoor and outdoor unit, with a minimum interval of 20cm, otherwise the communication of the unit will probably wor

Strany 77

Wired Controller IS-TT85015Table 5.1 Meaning of Each ErrorErrorErrorCodeErrorErrorCodeReturn air temperature sensor open/short circuited F1 Drive boar

Strany 78 - 5 Errors Display

Install of The Compact Panel Cassette Type Indoor Unit5 Smear freeze motoroil hereSpannerThread fasten(x4)Median sponge (attachment) (entwine the wiri

Strany 79

Technical SupportBefore calling technical support, please see the troubleshooting guide above. You may also visitour website at www.impecca.com for an

Strany 80

Install of The Compact Panel Cassette Type Indoor Unit6Sponge(attachment)Clamp(attachment)Below 4mmClamp Drain hoseSponge (gray)Fig.7Drain stepup pipe

Komentáře k této Příručce

Žádné komentáře